Dam-break simulation

How Fugu reproduced a dam-break experiment over an obstacle with 402,500 cells, validated against reference measurements in ~2 hours.

Industry
Hydraulics & Environmental
Physics
Multiphase flow - Fluid/structure interactions
Platform
HPC cluster

Dam-break simulation powered by WINTS

This video is hosted by YouTube. Loading it allows YouTube to receive technical connection data.

Objective

Demonstrate that Fugu, WINTS’ numerical engine, can reproduce the benchmark experiment described by Kleefsman et al. while keeping runtime low.

Simulation setup

The case uses a 402,500-cell mesh to capture interactions between water, air, and the solid obstacle. WINTS pre-launch checks validate the setup and recommend the optimal processor count.

  • 3D domain with 402,500-cell mesh and adaptive timestep
  • Automatic resource recommendations and input-compliance checks via WINTS guardrails
  • CPU count: 20
  • Native multiphase handling, avoiding complex remeshing

Results & validation

Water height (H1–H4) and pressure (P1–P2) probes match published measurements. The full run completes in about two hours, demonstrating the efficiency of a well-tuned HPC configuration with Fugu.